Single-incision laparoscopic surgery for totally extraperitoneal herniorrhaphy via umbilical incision: A report of 95 cases

Yizhong Zhang1,(), Junjie Chen2, Jiansong Tang3, Changlei Qi1, Yongfeng Shuai1, Lu Zhu2, Ronghua Chu2   

  1. 1. Department of General Surgery, The Affiliated Hospital of Medical School of Ningbo University, Ningbo 315020, China
    2. Department of General Surgery, Ningbo Beilun Hospital of Traditional Chinese Medicine, Ningbo 315800, China
    3. Department of General Surgery, Ningbo Beilun Third People's Hospital, Ningbo 315806, China
  • Received:2019-10-18 Online:2020-08-18 Published:2020-08-18
  • Contact: Yizhong Zhang
  • About author:
    Corresponding author: Zhang Yizhong, Email:

Abstract:

Objective

To summarize the technique of single incision laparoscopic surgery (SILS) via umbilicus for total extraperitoneal inguinal herniorrhaphy (SILS-TEP).

Methods

95 cases clinical data of SILS-TEP which were performed in the Affiliated Hospital of Medical School of Ningbo University from October 2018 to June 2019 were analyzed.

Results

95 cases underwent SILS-TEP and 2 cases were converted to conventional TAPP. The average unilateral hernia operation time was (66.74±10.95) minutes. There were 3 cases of seroma, 2 cases of infection in umbilical incision, no hematoma of scrotum, chronic pain, mesh infection and hernia of umbilical incision, and no recurrence during follow-up. The main techniques included: the improvement/construction of conventional single port and the operation with suction hook; the arc-shaped incision at the lower edge of the umbilicus was conducive to the concealment of scars; the cross operation of left and right hands; the separation of the hernia sac with electric hook or the separation clamp after being electrified.

Conclusion

It is safe and feasible to operate SILS-TEP under the condition of skilled operation and standard operation.

Key words: Hernia, inguinal, Single incision, laparoscopy, Total extraperitoneal inguinal herniorrhaphy