Chinese Journal of Hernia and Abdominal Wall Surgery(Electronic Edition) ›› 2020, Vol. 14 ›› Issue (04): 400-402. doi: 10.3877/cma.j.issn.1674-392X.2020.04.020

Special Issue:

• Clinical Article • Previous Articles     Next Articles

Effect of abdominal CT scan (low dose) on abdominal wall hernia

Chenpeng Liu1, Zhenyu Pan1,(), Xiang Gong1, Shurong Jin1   

  1. 1. Department of radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing 100040, China
  • Received:2020-03-09 Online:2020-08-18 Published:2020-08-18
  • Contact: Zhenyu Pan
  • About author:
    Corresponding author: Pan Zhenyu, Email:

Abstract:

Objective

To investigate the effect of CT abdominal scan (low dose) in the diagnosis of abdominal wall hernia.

Methods

Sixty-five patients with abdominal wall hernia admitted to Beijing Chaoyang hospital from January to December 2019 were selected for diagnosis. Normal dose of abdominal CT scan (260 mAs) was performed at the time of the initial clinical examination as the control group. In the subsequent abdominal enhancement, the plain scan sequence was reduced to 50% of the original dose (130 mAs), which was set as the observation group.

Results

The rate of excellent and good images in the control group was slightly higher than that in the observation group, but there was no significant difference (χ2=0.251, P=0.684). The CNR and SNR of the control group were 12.17±1.86 and 3.66±1.15, respectively, which were slightly higher than 10.26±2.16 and 2.87±1.06 in the observation group. The SD of the control group was 9.6±1.61, which was slightly lower than that of the observation group 11.5±2.51. The difference was statistically significant (t=0.685、0.375、0.411, P<0.05).

Conclusion

Abdominal CT scan (low dose) has a good effect on abdominal hernia. Compared with conventional dose, there is no significant difference in image quality and noise, but it can effectively reduce the radiation dose. Therefore, it is worthy of reference and use in the diagnosis and treatment of abdominal hernia.

Key words: Tomography, X-ray computed, Low dose, Diagnosis, Abdominal wall hernia, Application effect